Repower® RE10TX
Repower RE10TX – one-component structural repair material based on cement, containing polymer and fibres.
Conforms to EN 1504-3 / class R2
Application Areas
- Can be used on horizontal and vertical surfaces
- In the repair of reinforced concrete structures
- In protecting concrete from the effects of sulfates and chlorine
- In the repair and protection of marine structures
- In the repair and protection of underground historical monuments
- In repair and restoration of rough concrete surfaces with high strength
- In the repair of precast concrete elements
- In the repair of special coatings and surfaces with light and medium traffic loads
- For filling gaps in the connecting elements of forms
Advantages
- Mixes only with water, easy to apply
- Has thixotropic properties (not flowing)
- Has high adhesion to concrete and reinforcement
- Resistance to high pressure
- Resistant to freeze-thaw cycles
- Resistant to the effects of sulfates and chlorine
- Oil resistance
- Waterproof
- Does not shrink
| Product composition | Cement, mineral fillers and special chemical additives |
| Color | Grey |
| Pressure resistance - EN 12190 After 7 days | ≥ 50 MPa |
| Pressure resistance - EN 12190 After 28 days | ≥ 60 MPa |
| Bond strength to concrete EN 1542 | ≥ 2 MPa |
| Modulus of elasticity EN 13412 (28 days) | ≥ 20 GPa |
| Bending resistance EN 196-1 (28 days) | ≥ ≥ 9 N/mm 2 |
| Capillary water absorption - EN 13057 | ≤ 0.5 kg.m -2 .h -0.5 |
| Chloride ion count EN 1015-17 | ≤ 0,05% |
| Resistance to carbonation EN 13295 | dk ≤ control concrete (MC(0.45)) |
| Application thickness (one layer) | min. 10 mm, max. 40 mm |
| Temperature of the treated surface | +5°C +30°C |
| Operating temperature | -20°C +400°C |
| Application time | 45 min. |
| Possibility of movement on the surface | In 24 hours |
| Time for complete hardening | In 28 days |
| Density of the mixture | 2.25 kg/l |